Pulsed AC Ionizer_P/N : PA0901C

Pulsed AC Ionizer Using the pulsed AC high-voltage generator, the ion balance is relatively stable for a long time, and the cleaning cycle is long. The discharge needle (emitter) holder can be quickly plugged in and detached from the machine as well as convenient for cleaning. The discharge needle can be replaced separately prolong the service life of the whole machine. Fault alarm, can output the alarm signal to monitoring system Ion balance: ± 3V Decay time: high wind speed: 0.7S, low wind speed: 1.0S CE Certification, FCC Certification; OEM is acceptable.

User Manual_Pulsed AC Ionizer_P/N : PA0901C


Package Contents:     

Please carefully read this manual before use in order to correctly operate the product, and keep the manual properly for future reference.

Check the package contents firstly after unpacking.

1. Main body………………………………………………………………………………………………………………………1 pc

2. DC24V stabilization voltage power supply……………………………………………………………………1 pc

3. Alarm signal grounding cord…………………………………………………………………………………………1 pc

4. User manual…………………………………………………………………………………………………………………..1 pc


Product Overview:

This product is a type of electrostatic eliminator and belongs to the electrostatic and dust eliminating device with wind source (or air source). It is widely applied in electronic communication and precise instrument components for ESD protection and is an essential electrostatic and dust eliminating device in plastic products, printing, paint coating, membrane, film products, biological product, medicine, food packaging and other processing and manufacturing industries.      


Main Features:

      When the product is designed of internal structure, user’s using habit and maintenance convenience are taken into account. Three systems of Ionizer: high-voltage device, ion emission needle frame and air supply system are designed to insertion and extraction connection structure, and high voltage power supply and ion emission needle frame are combined to mold the standard high-voltage ion emission needle frame. The air supply system can be directly fixed on the needle frame. The user only needs to extract the needle frame to clean the emitter. needle and fan if required.

      In the event of ionizer breakdown, the user only needs to purchase and insert a new ion emission needle frame to allow re-functioning of ionizer without wholly scrapping. We implement the recycling preference policy “old for new service” for standard spare parts, and will analyze and dispose recycled parts in concentration, in order to advocate environmental protection, earth and environment preservation. 

      With function of automatic adjustment for positive and negative ions, the product still can maintain excellent ion balance and fast electrostatic eliminating capability for long-term use without manual adjustment.

      The product has functions of power input, operation indication (green light indicates operation display) and high-voltage operating abnormality indication (red light indicates fault). You may only press the speed control switch to select high, medium or low speed to adjust the air speed.

      Both front air window (air outlet) and rear air window (air inlet) can be opened. The user may remove the front and rear air windows to clean them, and add a dust screen on the rear air window as per the service environment.

      The emitter needle is made of special alloy materials. It is recommended to clean the emitter needle with sponge-headed swab or non-dust cloth-headed swab after the product has operated for 300 to 500 hours, to ensure continuous stability of electrostatic elimination and ion balance.

      The user may suspend this product on the workbench, or connect several ionizers with stainless steel tubes and screws as needed. Thus, the operation is free and simple.


Appearance and Sizes:

ESDMAN


Operation Place and Methods:

Ⅰ:Operation Place

      Install this product at the place where the operation panel indicator light and power switch are easy to be confirmed. Do not use the product at the place where the water and oil are contacted, high-temperature and humidity conditions, dust particles exist or combustion and explosion may occur. Do not block the air inlet and fully reserve the spatial height required for extracting the high-voltage ionization needle frame.

Ⅱ:Operation Methods

     Install the main body and attached support, and reserve three ¢4.5 mounting holes at the bottom of the support. Fix this product on the workbench or machinery equipment. Tighten the plastic lever at both ends.

     Connect the power, insert the output end of attached DC24V stabilized power supply into the “power input port” of the product and then connect the other end into the power socket of AC100~240V 50/60HZ.

     Connect the equipped grounding cord to GND . 

     Press the power switch, the green indicator light will be on and this equipment is going to work. The emitter needle will generate corona discharge. At this moment, you may hear the weak “zi-zi” sound. The fan operates to blow out a great deal of ion wind to quickly neutralize the static electricity charged objects in the area.

     Press the button “speed control” to select high, medium or low speed.

     In the case of high-voltage operation abnormality, the red indicator light will be on. The user may shut down the power (by switching off the power switch) and contact the supplier for repair, or replace the high-voltage ionization needle with a new one. Then, the equipment will operate normally after powered on.

     When the yellow indicator light is on, extract the ion emission needle frame to clean the discharging needle (electrode needle). Then, insert it, and the equipment will operate normally by pressing “reset” after powered on.

     Shut down the power if the equipment is not used.

     In the case of high-voltage operation abnormality, the red indicator light will be on. The user may shut down the power (by switching off the power switch) and contact the supplier for repair, or replace the high-voltage ionization needle with a new one. Then, the equipment will operate normally after powered on.

     When the yellow indicator light is on, extract the ion emission needle frame to clean the emitter needle. Then, insert it, and the equipment will operate normally by pressing “reset” after powered on.

     Shut down the power if the equipment is not used.


Specification:


Model

ESDMAN-PA0901C

Dimension

143*115*68 mm

Boost mode

Pulse DC

Operating voltage

± 7000 V

Ion balance line

Equivalent pulse control self - balance

Decay time

About 1.3 s

Ion balance

± 3V

Maximum speed

1.5 m/s

Maximum air volume

1.5 m3/ min

Input voltage

DC 24 V ± 5% 0.5A

Operating current

0.25A

Operation environment

Temperature: 0-50, Humidity: 35%- 65%

Optional
/Standard accessories

Extractable high-voltage ionization need frame, emitter needle seat, 
front air window, rear air window, DC fan,DC 24V power line

Product structure

Extractable high-voltage ionization need frame

Feature

Extractable high-voltage ionization need frame, snap joint front and rear air windows, 
remote monitoring output fault alarm signal, emitter needle cleaning indication function, 
auto-cleaning function of emitter needle (optional)



Discharge Time:

ESDMAN


 Abnormality Alarm Function:

The equipment is provided with the function of high-voltage ionization operation abnormality alarm. The high-voltage operation indicator light will turn red in the case of:

1. Too low high-voltage output

2. High- voltage output short circuit

3. High- voltage abnormal discharge


Daily Maintenance:

     Cleaning of front and rear air windows; remove the front and rear air windows to clean them with non-dust cloth after the equipment has operated for a period (about 500 hours). Install them after drying up to effectively prevent “secondary pollution”.

     Cleaning of emitter needle; dust and pollutants may accumulate at the front and in the vicinity of emitter needle. Clean it with the attached swab. Notice not to damage or loosen emitter needle.


Other Notes:

ESDMAN   Caution:Connect the grounding wire properly during use. Improper grounding will affect the electrostatic 

                            elimination or result in equipment damage.

                            Clean the emitter needle on a regular basis because its pollution affects the electrostatic elimination. 

                             The emitter needle is sharp at the front. Notice not to injure your fingers during cleaning.