High Frequency AC Ionizer_Stainless Steel Casing_H1201SAC
It is able to automatically clean the emitter point on time; 0-999 hours is adjustable; The cleaning brush automatically cleans the emitter point, which can reduce the time of manual cleaning. Alternatively, it can be manually cleaned within a few seconds;
Main Features:
› No electromagnetic interference.
› Quick maintenance: The front and rear gauzes and emitter point can be quickly dismantled for easy cleaning, maintenance and replacement.
› Outage memory: Start is not necessary after power-on; automatic start for keeping operation with the previously set parameters.
› The emitter point is made of the special alloy, which is not easily worn after use for a while.
› Monitoring alarm: High voltage and fan operation indicator light, anomaly alarm indicator light and buzzer alarm.
› Signal output: Alarm signal output, can be connected with the equipment transmission.
› Locking: After locking, all keys will be invalid and unlocking is required.
› Outage protection: After the front air window is taken down, the machine will be powered off.
› The casing and function can be customized according to the customer requirements.
Technical Data Sheet:
Part Number | H1201SAC |
Power Input | DC24V±5% |
Operating Power | Approx.12W |
Ion Generation Mode | Corona Discharging |
Power Supply | AC2200V |
LED Display | H.V | When the static is eliminated normally, the green indicator light will light up. |
When the static is eliminated abnormally, the red indicator light will light up (the buzzer will give an alarm). |
Fan | When the fan works normally, the green indicator light will light up. |
When the fan does not work, the red indicator light will light up (the buzzer will give an alarm). |
Air volume output | 2.5-4.5m³/min |
Decay Time | 1.0 sec @12" |
Ion Balance | ±10V |
Automatic cleaning time setting | 0-999 hours |
Ozone generation amount (ppm) | Within 0.04ppm (measuring distance 150mm) |
Environment Temperature | 0-40°C |
Environment Humidity | 20%-70%RH (no condensation) |
Dimension | 212x143x90mm |
(The bracket is included) |
Weight | 1.8 KGS |
Warranty | 1 Year |
Testing Result and Performance:
Operating Voltage: DC24V
Testing Voltage: ±1000V - ±100V
Temperature: 25°C
Distance | Ion Type | 300mm | 600mm | 900mm |
Decay Time | + | 0.6s | 1.4s | 2.2s |
- | 0.8s | 1.6s | 2.9s |
Ion Balance | + | ±10V |
- |
Notes:
1. Measurement method: Measured with a 20PF and 150mm Charge Plate Monitor
2. Decay time means the “fall time” from ±1000V - ±100V when the filter screen is not installed and the air volume is maximum.
3. The Charge Plate Monitor is located at the center line of the fan outlet.
Product Image:

Discharge Time: