Description

The ESD Glove Testing Fixture (Constant Area and Force Electrode) meets ANSI/ESD SP15.1 requirements for measuring the intrinsic electrical resistance of gloves and finger cots. It also measures their electrical resistance together with personnel as a system.


Operation

1. Fit a wristband snugly onto the wrist. 

2. Snap the wrist cord to the wristband. Use the included non-resistor wrist cord if performing a Low Voltage System Resistance Test per sections 6.6 and 6.7 of ANSI/ESD SP15.1. Use a one megohm wrist cord if performing a High Voltage System, High Resistance Test per section 6.8 of ANSI/ESD SP15.1. 

3. Plug the wrist cord into one input of the resistance meter. 

4. Attach the ESD Glove Testing Fixture to the other input of the resistance meter. 

5. Wear the glove on the same hand as the wristband and wait a minimum of 15 seconds before beginning the electrical measurement. 

6. Balance the ESD Glove Testing Fixture on the fingerprint side of the thumb or first finger of choice on the hand wearing the glove. 

7. Take a resistance measurement using the resistance meter.


Specifications

ESD Glove Testing Fixture 

Dimensions: 77mm x 25 mm x 102 mm 

Weight: 460g


Packaging

ESD Glove Testing Fixture *1


ESD Tester, Grounding Monitor,IonizationESD Glove Testing Fixture_001-9005_Rev.K02A2501.pdf