Main Features
▪ Plug and pull design
▪ Embedded high voltage power supply
▪ Automatic ion balance system
▪ LED indicator
▪ Abnormal signal output
▪ Tungsten emitter needle
▪ Variety of nozzles
▪ Quickly clean or replace the emitter needle for quick maintenance.
▪ No high voltage wiring, safety and convenient
▪ Ion balance can be 0±15 V
▪ Equipped with normal operation indicator and abnormal indicator
▪ Can be connected to the operation station or equipment alarm
▪ Long-term use is not easy to wear, can be applied to clean room
▪ It's available for different applications.
Specifications
Part Number | HN-04 Nozzle Ionizer |
Power Input | DC24V±5% |
Power | 4W |
Ionization Technology | High Frequency AC Corona Discharge Method |
Applied Voltage | ±2200V |
Applied Voltage Frequency | 68Khz |
Emitter Material | Tungsten |
Ion Balance Control | Auto Ion Balance without adjustment |
Decay Time | 0.3S as fastest (0.5Mpa air pressure) |
Ion Balance | ±15V |
Used pressure | 0.01–0.7 Mpa Clean Dry Air (CDA) or Nitrogen A maximum of 0.5Mpa is recommended |
Alarm Prompt | POWER power indicator; H.V high voltage operation indicator;ALARM high voltage fault indicator; C.C cleaning indicator |
Ozone Production | <0.05 ppm (0.02Mpa air pressure @ 300mm distance) |
Operating Environment | 5-40°C;20%-70%RH( No condensation) |
Shell Material | Body: ABS,Emitter needle:tungsten, Metal Shield: stainless steel,Mounting bracket: stainless steel |
Air Pipe Outlet | 1/8 standard air pipe connector (6mm air pipe) |
Installation | Air nozzle with mounting bracket |
Dimension | H92*W53*D21mm |
Weight | 118g |
Warranty | One year |
Certification | CE FCC |